中文 | English
Service Support
Xin Rui laser for all types of enterprises to provide the best quality the most comprehensive laser solutions

Extend the life of the glass laser tube several maintenance points?

Date:2018-01-20 Author:Xiangyang Xin Rui Laser Technology Co., Ltd. Views:5973

(1) The operating environment of the machine is better, the power supply voltage should be stable, if the voltage fluctuation is too large, configure the regulated power supply. The machine should be placed smoothly and can not work under the condition of large vibration and dampness.


(2) The laser current can not be too large, it must be below 20mA, and as far as possible to meet the carved depth and speed conditions to reduce the light intensity, 13-17mA is the more appropriate current range.


(3) laser tube is a heating element, we must ensure the quality and quantity of recycled water: Quality --- to ensure clean and free of debris, regular replacement of circulating water (two days), changing the water must be carried out when the machine does not work; Quantity --- To ensure adequate circulating water (20Kg above), to ensure that the circulating water temperature at 5-25 ℃.


(4) To meet the requirements of the work conditions, to optimize the working methods to maximize the life of the laser tube. For example, try to use more cutting methods.


Common Problem

Laser tube life extension on the issue of maintenance?

For example, we often use the laser cutting machine, with a period of time, the laser tube will become less power after aging, and some things do not slow down will not be able to penetrate the. A...

Date:2018-01-21 Views:6326

Laser tube current is too small will affect the life of the laser tube do?

Laser tube has a markedly good work current size, the general use of the laser tube, we will be in accordance with the size of each laser tube power to advise customers to use a certain range of c...

Date:2018-01-21 Views:6646

Laser tube does not light the reason?

1、the power control line and the positive and negative links are correct;2、 if the appearance of no damage, the color of the partial discharge of blue or purple partial leakage of gas, high pressure d...

Date:2018-01-21 Views:10173